Poly-Vent ASSEMBLY INSTRUCTIONSIMPORTANTPlease read these instructions carefully before you start to assemble this vent system. Save these instructio
10NEW OREXISTINGFRAMENominal Poly-VentDistance "A" Distance "B"2 ft19" 50-1/2"3 ft 31" 38-1/2"4 ft43" 26-
SECTION A-A11AA3/8"CORNER HOOPROLL-FORMED RAILSAND SKIRTING SHOULDBE FLUSH WITH OUTSIDEOF CORNER HOOPEDGE OF TOP & BOTTOMGUTTERS SHOULD BEMOU
12INSTRUCTIONS:IMPORTANT NOTE: ALL FASTENERS MUST BE INSTALLEDWITH THE BOLT HEAD ON THE INSIDE OF THE POLY-VENTFRAME TO PREVENT DAMAGE TO THE POLY-VEN
13INSTRUCTIONS:4A. INSTALL END PANEL. MAKE SURE YOUARE USING THE CORRECT PANEL (LEFTHAND OR RIGHT HAND).4B. AFTER END PANEL IS PROPERLY FITTEDINTO POS
ATTACHINGTHE TOPOF REAR GUIDE14INSTRUCTIONS:5A. INSTALL FIRST SET OF GUIDES. THE GUIDES THAT MOUNT TOTHE INSIDE (STRUCTURE SIDE) ARE MOUNTED INSIDE TH
15INSTRUCTIONS:6A. INSTALL THE ADJOINING SECTIONS OF TOPAND BOTTOM GUTTERS.6B. OVERLAPPING SECTIONS SHOULD BE ASSEMBLEDAPPROPRIATELY FOR PROPER WATER
16BLOWERMOUNTINGBRACKET5/16" x 1-1/2"HEX BOLT5/16" LOCK WASHER5/16" HEX NUTMount the blower mounting rail to your structure's
171. Thread the Poly-Vent film through the Poly-Vent frame.USE CAUTION WITH THIS PROCEDURE. DO NOT LET THE POLY-VENT FILM SNAG ON OR CATCH ANY FRAME P
18"THIS SIDE UP" DECALThis drawing illustrates where to locate the air inlet(s) on your Poly-Vent.POLY-VENT IIBLOWERTOPBOTTOMPOLY-VENT IIIBL
195. Next, insert the flex tube into the opening.Make sure that there is no sharp wireexposed that may puncture the Poly-Venttube.1. Once you have loc
27725 Danville AvenueP.O. Box 458Castle Rock, MN 55010(651) 463-7009(651) 463-2479 faxwww.poly-tex.comU.S. & Canada Toll Free800-852-3443
20Thermostats for the Poly-Vent system should be mounted approximately centered between each sidewall and centered fromfront to rear of the structure.
21Thermostats for the Poly-Vent system should be mounted approximately centered between each sidewall and centered fromfront to rear of the structure.
22BLACKL1BLUE NOT USEDREDBLACKWHITEGREENWHITEWHITEBLACKREDPINKBLUE NOT USEDVIOLET NOT USEDBROWNBLACKL1BLACKTOP BLOWERBLACKTOPBLOWERWHITEBOTTOMBLOWER B
23IMPORTANT:This drawing illustrates end views of thePoly-Vent. When inflated, the Poly-Vent tubingseals will form a "zig-zag" profile. If y
3LENGTH RELATED COMPONENTS(Lengths listed are nominal, actual length is 1" longer)Component8ft LongPV6000PV6001PV60026ft LongPV6019PV6022PV60252f
4Part Number2ft 3ft 4ft 5ftComponentNominal Poly-Vent HeightHEIGHT RELATED COMPONENTS(Lengths listed are nominal Poly-Vent heights, actual heights var
54-1/2" END CLIPPV40011/4" HEX NUTNB18701/4" LOCK WASHERNB18601/4" x 3/4" HEX BOLTNB1840#12 x 1"SELF-DRILLING SCREWNB180
6#3 PV PLUGPK50863.25" HOSE CLAMPPT2420BLOWERPT24483" x 5' FLEX TUBINGPT2437BLOWER MOUNTINGBRACKETPT2409AIR TRANSFERGASKETPT24365/16&qu
7DISTANCE"A"NOMINALPOLY-VENTHEIGHT19"31"43"55"2 FT3 FT4 FT5 FT"A"CENTERLINEOFFASTENERS"A"CENTERLINEO
P:\ACAD2\MANUALS\POLY-VENT\PG 8 GENERAL PART ORIENTATION.idw8BACKER PLATETOP GUTTERFRONT PANELBOTTOM GUTTEREND PANEL4-1/2" END CLIPSIDECLIPBACKPA
9BACKER PLATETOP GUTTERFRONT PANELBOTTOM GUTTEREND PANEL4-1/2" END CLIPSIDECLIPBACKPANELEND VIEWBACKER PLATETOP GUTTER4-1/2" END CLIPFRONTPA
Comments to this Manuals